Application: | Construction, Industrial |
---|---|
Voltage: | Low and Medium Voltage Cable |
Current: | DC & AC |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Product Description
1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by the standard of ASTM, BS, DIN and AS/NZS or other standards as request.
2. Rated Voltage of XLPE Cable:
0.6/1KV 6/10KV;8.7/15KV;12/20KV;18/20KV;21/35KV;6/35KV
3. Construction of XLPE Cable:
Conductor: Copper or Aluminum
Insulation: XLPE
Inner sheath: PVC or PE
Armoured: Galvanized steel tape, Galvanized steel wire
Outer Sheath: PVC or PE
NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.
Also can do according to the customer's request.
4. Characters of XLPE Cable:
a.Max Long-time operating temperature of XLPE insulated cable is 90°C
b.Installing temperature of cable should not be less than 0°C
c.Max short-circuit temperature does not exceed 250°C, Not more than5 Sec.
d.Unable be laid without the limit of fall with enough mechanical pull, Single-core cable can not be laid in an iron tube or fixed by circled iron tools around cables
5. Description & Application of XLPE Cable:
TYPE |
NAME |
Main Application |
|
CU core |
AL core |
|
|
YJV/YJY |
YJLV/YJLY |
XLPE insulated, PVC/PE sheathed power cable |
For laying indoor, tunnel, canal and underground. Unable to bear external mechanical forces, but bear the traction force during laid |
YJV22/YJV23 |
YJLV22/YJLV23 |
XLPE insulated, steel tape armored, PVC/PE sheathed power cable |
For laying indoor, tunnel, canal and underground.Able to bear external mechanical forces, but unable to bear the large pulling force |
YJV32/YJV33 |
YJLV32/YJLV33 |
XLPE insulated, thin steel wire armored, PVC/PE sheathed power cable |
For laying in the shaft, water underground will large difference of level. Able to bear external mechanical forces and moderate pulling force |
YJV42/YJV43 |
YJLV42/YJLV43 |
XLPE insulated, thick steel wire armored, PVC/PE sheathed power cable |
For laying in water and seabed.Able to bear positive pressure and pulling force |
6. Advantage:
a. Excellent electric and mechanical characteristics
b. Best Resistance chemical corrosion and heat-aging, environment stress and flame-retardant
c. Simple in structure, Convenient to use
d. Reduce costs.
British Standard MV cables Voltage Rating
BS6622 - standard British MV cable 6.35/11kV 19/33kV
BS7835 - LSZH British MV cable 6.35/11kV 19/33kV
European standard MV cables Voltage Rating
N2XSY - single copper core XLPE insulated with PVC over sheath 6/10kV 12/20kV 18/30kV
N2XS2Y - single copper core XLPE insulated with PE over sheath 6/10kV 12/20kV 18/30kV
NA2XSY - single aluminum core XLPE insulated with PVC over sheath 6/10kV 12/20kV 18/30kV
NA2XS2Y - single aluminum core XLPE insulated with PE over sheath 6/10kV 12/20kV 18/30kV
N2XSEY - 3 copper core XLPE insulated with PVC over sheath 6/10kV
N2XS(F)2Y - single copper core XLPE insulated with water blocking powder and PE over sheath 6/10kV 12/20kV 18/30kV
N2XS(FL)2Y - single copper core XLPE insulated with water blocking powder and aluminum tape tightly bonded to PE sheath 6/10kV 12/20kV
NA2XS(F)2Y - single aluminum core XLPE insulated with water blocking powder and PE over sheath 6/10kV 12/20kV 18/30kV
NA2XS(FL)2Y - single aluminum core XLPE insulated with water blocking powder and aluminum tape tightly bonded to PE sheath 6/10kV 12/20kV 18/30kV
Product Name | YJY XLPE Insulation LSOH Sheathed Flame Retardant Power Cable |
Model/Standard | CU/XLPE/LSOH, IEC 60331, IEC 60502, IEC 60227, IEC 60331, IEC 601034, IEC 60754, GB/T 12706-91, GB306.1-2001, GB/T18380.3-2001, CE, CCC, KEMA |
Conductor Material | Circular stranded copper conductor, conforms to IEC 60228 class 2 |
Insulation Material | XLPE/A |
Inner Covering | LSOH |
Sheath Material | LSOH, black |
Insulation Color | As per standards or customer requirement |
Rated Voltage | 0.6 kV |
Max. Conductor Temperature | Normal: 90°C; Short circuit (5 seconds): Maximum conductor temperature not exceeding 250°C |
Min. Ambient Temperature | Cable should be preheated if ambient temperature is below 0°C |
Min. Bending Radius | Single-core cable: 20(d+D)±5%; Multi-core cable: 15(d+D)±5% |